Range Rover P38 4.0 automatic temperature control fault link lead wiring YMQ501010

More Views

  • Range Rover P38 4.0 automatic temperature control fault link lead wiring YMQ501010
Range Rover P38 4.0 automatic temperature control fault link lead wiring YMQ501010
Excl. Tax: £15.00 Incl. Tax: £18.00

Availability: In stock

Range Rover P38 4.0 automatic temperature control fault link lead wiring YMQ501010
OR
Description

Details

This part is the link lead wiring which was fitted under warranty to 4 litre Range Rover P38

Genuine Land Rover part new old stock. Clearance price. 

The below information is from Land Rover Workshop Manuals website. 

Control Assembly: All Technical Service Bulletins
A/C - 'Handbook Symbol' Displayed on ATC Display

No: 82/01/03/NAS
Ref:
Issue: 1
Date: 27 February 2004

Automatic Temperature Control Fault 
Display Correction

AFFECTED VEHICLE RANGE:

Range Rover (LP)
up to 2A427128

SITUATION:

HANDBOOK SYMBOL ILLUMINATED ON THE ATC DISPLAY

When the coolant temperature reaches 97°C (207°F) and stays at or above that temperature for ten minutes, the Automatic Temperature Control (ATC)
diagnostic system will illuminate the handbook symbol on the ATC display. The diagnostic fault code in the ATC panel software is set too low for
normal vehicle operating conditions in very hot climates.

RESOLUTION:

INSTALL RESISTOR TO ADJUST ATC INPUT

NOTE:

Installation of the resistor will "adjust" the displayed output temperature seen in real-time T4 monitoring. Comparing the ATC sensor output after the
modification with other coolant temperature information in real time can be misleading.

CAUTION

It is important to verify that there is not a mechanical cause for high coolant temperatures. Inspections for leaks and verification of the coolant level
as well as proper fan and thermostat operation should all be verified.

Should a customer express concern regarding the appearance of the handbook symbol during hot weather operation, the DTCs should be examined to
determine if the vehicle has a fault for the heater core temperature sensor. If that fault is flagged on vehicles built before the above VIN, follow the
rectification procedure in this TIB to install an in-line resistor link lead between the heater temperature sensor and the electrical harness.

Also refer to TIB 80/03/96/US for information relating to intermittent operation of early vehicle heater core sensors. Sensor date codes should be (April
1996) or higher.

PARTS INFORMATION:

YMQ501010

Link lead

Qty 1

AS400 WARRANTY CLAIMS (CANADA ONLY)

82.20.94

Time 0.10 hrs.
Install ATC system wiring resistor link lead

FAULT CODE: A

Please contact us if you have any questions

 